The cooler element of the
plate-fin heat type
exchanger is superimposed
aluminum and brazed in a
furnace at controlled
temperatures of around
600℃
Maximum dynamic
pressure:20 bar.
Maximum static pressure:
30 bar.
Max. operating
temperature:120℃
(Excluding the fan motor.)
To protect the heat
exchanger , when installed
on the return line of a
system or when the
equipment is started with
cold oil , a by-pass valve
should always be mounted
in parallel to the exchanger
in order to avoid excessive
pressure surges.
An alternate piping method
using a separate circuit from
the reservoir with a small
pump to drive the oil
through the heat
exchanger .
Filters are often
incorporated into these side
circuits or kidney loops , as
they are sometimes called .
For all applications , with the
exception of oil cooling , it is
recommended to consult
our technical department .